Rack End Clamp — Technical & Quality Specification

DOC-000061SpecificationINTERNALPublishedCurrent version 1

Document content

Version 1.0, as stored by Documents / Knowledge

Rack End Clamp — Technical & Quality Specification

FieldValue
Document numberDOCM-2026-000020
Document typeSPEC
Version1.0
StatusPUBLISHED
ClassificationINTERNAL
SpaceQMS — Quality Management System
FolderSpecifications
ApplicabilityTARGETED
Effective from2026-07-01
Controlled issuerLatha Menon
ReviewerRakesh Iyer
ApproverSunil Bhattacharya

1. Purpose

Define controlled technical and quality expectations for the purchased rack end clamp.

2. Controlled item

ERP item ITM-COMP-CLAMP — Rack end clamp. Base UOM EA; BUY; inventory item and purchasable flags active.

3. Requirements

The clamp must conform to the approved item design and controlled acceptance criteria. Incoming quality may evaluate CLAMP_TENSILE_N and SURFACE_FINISH, which are controlled inspection characteristics. A historical passing result must not be used as a substitute for the approved tensile acceptance criterion.

4. Verification and acceptance

Inspect under the Incoming Inspection Procedure. Record the actual numeric tensile result when tested and descriptive finish observations where applicable, then record PASS/FAIL against the approved criterion.

5. Nonconformance

Nonconforming quantities are held/dispositioned according to the Nonconforming Material & Quality Disposition Procedure. Partial release and partial return are allowed only when supported by recorded quantities and evidence.

6. Records and traceability

Retain item, supplier/purchase/receipt, inspection result and disposition references.

7. Notes

Where a numeric acceptance limit is not stated in this specification, the current approved acceptance criterion is applied by the relevant controlled inspection process.

Identification and traceability

The item must remain identifiable by its approved item reference and, where applicable, lot, batch, receipt or other traceability information. Packaging, handling and inspection records should preserve that identity so that a later quality decision can be related to the correct material or component.

Acceptance and nonconformance

Acceptance decisions are made using the current approved criteria and the applicable inspection procedure. A passing historical result is evidence about that inspection; it is not itself a specification limit. Where a requirement cannot be evaluated or a controlled criterion is unavailable, the affected material remains under quality control until the issue is resolved.

Handling and preservation

Material should be protected from avoidable damage, contamination, deterioration or mixing that could affect its intended use or make traceability unreliable. Any observed condition that could affect conformity is recorded and evaluated before release.

Change control

Technical changes to this specification are reviewed and approved through the controlled-document process. The effective version at the relevant business time governs new inspections and acceptance decisions unless an explicitly authorized deviation applies.

Applies to and related enterprise items

Canonical relationships

Related documents

Source: Documents / Knowledge document relations